Window lead-through 3C2V, 22cm 70250
Our prices are based on several factors, such as the current exchange rate, product availability, distributor terms and more.
Window lead-through 3C2V, 22cm
The window lead-through is designed for pulling a coaxial cable through a window without the need for drilling. It is a practical method of cable routing that is quick and simple. The pass-through is fitted with practical F connectors at both ends.
Installation of the antenna downlead without the need to drill the window frame. The cable can be pinched in the window without damage.
Technical data:
shielding coverage: 28 %
max. constant resistance at 20 °C, (Ohm/km) - outer core: not stated
warranty period: 2 years
APE = air dielectric: no
FPE = foam dielectric: not stated
min. bending radius single/multiple: not stated
sales package: 1 pc, PE bag
recommended types of connectors - F crimp: not stated
suitable for outdoor use: yes
inner conductor diameter: 0.5 mm
recommended types of connectors - F screw: not stated
PE = polyethylene dielectric: not stated
UV resistant: yes
insulation resistance between cores at 20 °C (MOhm/km): not stated
max. attenuation at 20 °C (dB/100m) 2 000 MHz: not stated
min. return loss at 20 °C (dB) 600–900 MHz: not stated
min. shielding attenuation (dB) 10 ~ 800 MHz: not stated
dielectric type, diameter: PE 1.6 mm
max. attenuation at 20 °C (dB/100m) 1 000 MHz: not stated
PES = foil layer: not stated
coaxial cable type: 3C2V
min. return loss at 20 °C (dB) 300–600 MHz: not stated
max. attenuation at 20 °C (dB/100m) 650 MHz: not stated
max. constant resistance at 20 °C (Ohm/km) - inner core: not stated
min. return loss at 20 °C (dB) 10–300 MHz: not stated
installation temperature: +5 °C to +60 °C
max. attenuation at 20 °C (dB/100m) 860 MHz: not stated
weight (kg/km): not stated
packaging method - length: 22 cm
reduction factor: 0.81
capacity (pF/m): 53
impedance: 75 Ohm
max. attenuation at 20 °C (dB/100m) 10 MHz: not stated
outer sheath diameter: 3 mm
shielding I. foil: no
inner conductor material: copper (Cu)
shielding diameter: 32×0.12 mm?
shielding material: copper-clad aluminum (CCA)
max. attenuation at 20 °C (dB/100m) 450 MHz: not stated
shielding II. foil: not present
packaging method - type of spool: not stated
packaging method - meter marking: not stated
number of shields: 1
storage temperature: -20 °C to +75 °C
outer sheath material: PVC
max. attenuation at 20 °C (dB/100m) 100 MHz: not stated
intended use: replacement for wall drilling
reaction to fire class: not subject to CPR
hazardous substances: not subject to CPR
number of shielding wires: 32×0.12 mm
outer sheath color: white
construction of power conductors: not stated
insulation of power conductors: not stated
color of insulation of power conductors: not stated
cross-section of power conductors: not stated